Lemax 2 mm P membrane - PE film is improved versatility of ammunition, can be installed in all positions require operation at low temperature, anti-radiation and mechanical pressure medium.
Lemax membrane 2 mm P - PE can be installed in:
- Typically a layer roof system.
- Roof system combines two layers of reinforced fiberglass.
- Waterproofing for toilets and wet areas within buildings, concrete.
ADVANTAGES
- Easy Installation (equal to warehouse)
- High mechanical properties.
- Absolute Waterproofing
- Bending cold plastic from -2 ° C or higher.
- Works well in high temperature conditions.
- Adhesion on any surface.
- Anti-deformed well.
- Friendly environment.
| Properties | Test method | Unit | Typical values |
| POLYETILEN FILM (PE) BITUM WATERPROOFING MEMBRANE APP LEMAX IMPROVEMENTS | |||
|
Length Width Thickness Volume on the mineral grains |
EN 1848-1 |
m m mm kg/m² |
10 1 2 4;4,5;5 |
| Soft spot | ASTM D -36 | ºC |
≥ 150 |
|
The level of penetration 25ºC 60ºC |
ASTM D -5 |
dmm |
15 to 25 60 to 80 |
|
Cold plastic bending Testing hot steam Reinforced |
EN 1109 EN 1110 |
ºc ºC |
0 to –2 120 Polyester fabrics, not knitted |
|
The intensity maximum stretch along horizontal |
EN 12311-1 |
N/5cm |
750 600 |
|
Maximum conductivity along horizontal |
EN 12311-1 |
% % |
≥ 40 |
|
The intensity of the maximum stretch ends along horizontal |
EN 12371-1 |
N/5cm n/5cm |
650 500 |
| Water absorption | EN 1107-1 | % | Maximum 0:15 |
| Let the steam through | EN 1931 | μ | 80.000 |
| Adhesion to concrete | EN 13596 | N/cm² | 40 |
| Dielectric constant | ASTM D-150 |
- | 2.5 |
| Dielectric strength | - | Kv/mm | 14 |
| The number of particles in the surface mineral loss | ASTM D -4977 | gm/m² |
Less than 200 |
APPLICATION INSTRUCTIONS
Lemax lining method to the repository, fastened or glued to the substrate depending on the requirements of the project.
Do not drop or throw rolled coil during discharge.
To avoid inserting the membrane into the corners, so handling the edges covered with sand and cement cross at right angles.
Waterproof surface must be clean, dry, remove dust and smooth, with surface irregularities should do more layer of cement sand screed.
Before the membrane lining Lemax scan.
Spread the membrane and placed in line.
Ties inside each roll must be adjacent cover 10 cm and tie the end of each coil adjacent to the cover 15 cm.
Roll half the film without changing direction.
Slowly cover the membrane, at the same time all the hard bottom (The system fully mounted) with propane to warehouse until burning plastic membrane and gradually flow out, creates a bonding between film and substrate.
Then the storehouse and the end flap to create seams, hand print on the film down. Difficult to use caution, not so long at a difficult point.
With tilt, should the construction of low vertical edge of the roll so that orthogonal to the inclined surface, the covering flap must be placed above the mat before ....
SAFETY
- Store in a dry and ventilated and prevent harmful elements such as sun, rain, storms ...
- The waterproof roll must be transported and stored in a vertical state, not so much rolled sheets in a pallet and to the core in the middle to prevent distortion dented membrane
Vietthai trading co.,ltd Head Office: Lot. K81C Thu Trung - Dang Lam – Hai An Dist – Hai Phong City, VietnamTel: 0313.558.619 / Fax: 0313.558.690 Email: chivietthai@chongtham.vn Website: www.Chongtham.vn :: www.vietthaico.com |
Branch in Hanoi P202 - C6 Building Blocks 2 - My Dinh 1 Urban - Tran Huu Duc St - Tu Liem Dist – Ha Noi City, VietnamTel: +84-4-6287 4144 / Fax: +84-4-6287 4147 Email: vietthai@chongtham.vn Website: www.Chongtham.vn :: www.vietthaico.com |