| Sika® BituSeal T-140 SG |
Sika® BituSeal T – 140 SG (0°C) is a torch-on sheet waterproofing membrane that is flexible to 0°C. It is based on APP (atactic poly-propy-lene) modified bitumen, reinforced with polyester non woven fabric. It has a slate granule broadcast surface and the reverse is faced with a polyethylene film to ease installation works.
Uses
- Waterproofing and damp-proofing of the exterior walls of base-ments against percolating water and damp soil.
- Waterproofing of retaining walls
- Waterproofing on flat roofs under protective layers or ballast
- Waterproofing on flat and exposed roofs and under tiles
- Waterproofing on balconies/terraces under tiles
ADVANTAGES
Resistant to ageing
Resistant to weathering with improved durability
Good tensile strength and elongation
High resistance to water vapour (non-vapour permeable)
Good dimensional stability
Flexible at low temperatures
Easy to install with the torch-on method
Not resistant to root penetration
Suitable as top layer for multi layer installations
Good resistance to mechanical impact
Must be installed on suitable primed, uniform and smooth sub-strates such as concrete and brickwork
PRODUCT DATA
| Appearance/Colours |
Rolled sheet membrane, reinforced with polyester non woven fabric Surface: slate granule broadcast, Reverse: polyethylene film to ease in-stallation |
|
| Membrane thickness |
4.00 mm |
|
| Colour | black |
|
|
Packaging |
Roll size: 1.00 m (roll width) x 10.00 m (roll length). Unit weight: approx. 4.8 kg/m2 |
|
|
Storage |
Dry, cool, shaded place (storage temperature +5oC to +35oC). | |
|
Shelf life |
4 years from date of production. |
|
| TECHNICAL DATA | Certificates | |
|
Length |
10.00 m (-1%) | EN 1848-1 |
|
Width |
1.00 m (-1%) |
EN 1848-1 |
|
Effective Thickness |
4.00 mm (± 5%) |
EN 1849-1 |
|
Mass per Unit Area |
- |
EN 1849-1 |
| Water Tightness |
≥ 60 kPa |
EN 1928-B |
| Flexibility at low Temperature | 0ºC |
EN1109 |
|
Flow Resistance at elevated Temperature |
To elevated temperatures:≥120°C |
EN 1110 |
|
Max. Tensile Strength |
700 N/50mm (±20%) 600 N/50mm (±20%) |
EN12311-1 |
|
Elongation |
45% (±15%) 45% (±15%) |
EN12311-1 |
| Dimensional Stability longitudinal transversal | <0.25% | EN 1107 |
|
Resistance to Impact |
1>=600 mm | EN 129691 |
|
Tear strenghth (nail shank) |
160 N (± 30%) (nail shank) |
EN 12310-1 |
Shear Resistance of Jiont |
≥ 400N / 50 mm |
|
| Acclerated Ageing T |
No defects Long term exposure to UV radiation according to EN 1297 Pass Long term exposure to elevated temperatures according to EN 1296 flexibility at elevated temperatures >+120°C (from -10°C) By long term exposure to UV radiation and elevated temperatures according to EN 1296 / EN 1297: By long term exposure to UV radiation and elevated temperatures according to EN 1296 / EN 1297:600 N / 50 mm, 600 N / 50 mm Water tightness: ≥ 60 kPa |
N1296
EN 1110 |
| Water Vapour Transmission Property | <=0.2 g / 24 hours / m2 | ASTME96 |
| External Fire Exposure | Class F roof (t1-4) | ENV1187 |
| Reaction to Fire | Class F | EN 13501-1 |
SUBSTRATE QUALITY
Clean, sound and dry, homogeneous, free from oils and grease, dust and loose or friable particles. Horizontal surfaces must be sloped > 1.5%.
APPLICATION CONDITIONS/LIMITATIONS
Substrate Temperature: +5°C min. / +65°C max
Ambient Temperature: +5°C min. / +50°C max.
Substrate Moisture Content: <=25 %
Relative Air Humidity: <= 85 %
APPLICATION INSTRUCTIONS
The cold applied bituminous primer shall be applied on the substrate for the first membrane layer as followings: Application by brush, roller, or airless spray. Waiting time is dependent on the temperature, for the primer to complete evaporation. (Note: Priming is not required for the second and further membrane layers).
The membrane is fully bonded to the substrate by the torch-on method using a gas torch. Unroll and position the membrane roll with the polyeth-ylene film surface on the substrate. Roll out half a roll length, heating the membrane reverse with the gas flame until it melts the polyethylene film and bitumen mass, and allowing continuous unrolling. A bead of liquid bitumen must be visible on the underside of the roll. The torch-on mem-brane must be firmly pressed onto the substrate in order to avoid air entrapment using a special roller or heavy brush. Repeat this procedure with the second half of the roll. All membranes must be overlapped by a min. 100 mm. The seams must be finished with a roller to prevent the formation of any gaps or voids.
HEALTH AND SAFETY
Wear protective clothing, gloves and goggles. Do not smoke next to the gas flame.
Caution: Too extensive heat on bitumen material by torching with gas flame can ignite bitumen and cause dangerous fire. Local security regulations must be observed.
Vietthai trading co.,ltd Head Office: Lot. K81C Thu Trung - Dang Lam – Hai An Dist – Hai Phong City, VietnamTel: 0313.558.619 / Fax: 0313.558.690 Email: chivietthai@chongtham.vn Website: www.Chongtham.vn :: www.vietthaico.com |
Branch in Hanoi P202 - C6 Building Blocks 2 - My Dinh 1 Urban - Tran Huu Duc St - Tu Liem Dist – Ha Noi City, VietnamTel: +84-4-6287 4144 / Fax: +84-4-6287 4147 Email: vietthai@chongtham.vn Website: www.Chongtham.vn :: www.vietthaico.com |